Your wholesale in
the rhine-main area
Free shipping From 150€ goods value (GER) ***
Only valid for deliveries within Germany, except forwarding goods.
Rapid delivery Shipping with GLS & UPS ***

EbV Delta+ 233B set

EbV Delta+ 233B set
This product is currently not available.

Re-available from: not possible to specify

  • 51001086
  • Neu
Weather-compensated two-stage heating control with circulation pump logic, three-step output and... more
Product information "EbV Delta+ 233B set"

Weather-compensated two-stage heating control with circulation pump logic, three-step output and storage electronics

Control functions

Two-point control loop for weather-compensated control of a boiler. The boiler temperature is controlled according to the outdoor temperature, the heating curve and the room set points. With a low outside temperature, a correspondingly higher boiler temperature is run and with an increasing outside temperature, the boiler temperature decreases to the bottom of the heating curve or to the fixed value of the boiler minimum limit. The minimum limitation can be set between 10 and 60°C depending on the boiler type. Due to the gliding boiler operation, the radiator heating system is controlled directly and without a mixer.

Three-point control loop with PI characteristic for weather-compensated control of an underfloor heating system or a radiator heating system The downstream three-point control is operated via a mixer by means of a servo motor. The running time of the motor can be between 1 and 4 minutes and can be adjusted on the device if necessary. The control characteristic is set via a separately acting heating curve. On request, a remote control or a room sensor for room temperature monitoring can be connected to a heating circuit.

Electronic storage tank temperature control with automatic storage tank priority circuit and electronic charging pump overrun. The storage tank temperature is determined by means of a potentiometer from the controller. If the hot water temperature falls below the value set at the set point adjuster, the controller switches off the circulation pump and starts the charging pump and the burner. This ensures immediate heating of the domestic hot water. After heating has been completed, the charging pump after-running starts to function for approx. four minutes. The heating operation is then continued.

Delivery contents:
1x controller Delta+ 223B
1x exterior sensor AF 200
1x flow sensor VF 202
1x boiler immersion sensor KVT 20/2/6
1x tank immersion sensor KVT 20/5/6
1x connection clamp BL 13 red
1x connection clamp BL 13 blue

Related links to "EbV Delta+ 233B set"
Did you see the article cheaper?

Seen cheaper?

You are also welcome to attach an attachment. Accepted formats are: jpg, png, bmp or pdf

The fields marked with * are required.